Design Department with Experimental Pilot Plant at INP AS RU was organized in 1979. for carrying out experimental pilot design activities according to the results of scientific-research works, carrying out in scientific departments of the Institute of Nuclear Physics. |
Director of the Design Department with Experimental Pilot Plant
Ergashev Khamidulla Abdullaevich
The two-radial radioisotop level-measuring assembly LMRR-1
is intented for discontact level measurement of liquid mediums at closed capacities in chemical and other fields of industry. It is installed(placed) in the external surface of capacity’s cover.
| The measurement range | from 0,5 to 6,0 m |
|
The basic errors |
<3 % by thickness of cover up to 10mm |
|
Working temperature range
|
from 30 to +50 С |
| The explosion-protection level |
1 Exd II CT5 |
|
The output signal level - 0 - 5 mA и 4 -20 mA |
The two-radial radioisotope density measuring facility
It is intented for discontact density measurement of liquid mediums in closed and open capacities, pipelines in chemical, oil-refining and other fields of industry.
It can be used as transducer (sensing element) determination of two mediums division. It is installed in the external surface of capacity by diameter no less than 250 mm with thickness of the wall up to 10 mm.
| The measurement range | from 600 to 2900 кg/м3 |
|
The absolute errors - |
<5 кg/м3 at thickness of the wall up to 10 mm |
| Working temperature range | from -30 to +50 С |
| The explosion-protection level | 1 Exd II CT5 |
| The output signal level | 0 - 5 mA и 4 -20 mA |
Simplified Gamma-Counter (Meter) SGM-1M
It is intended for comparative activity measurement of biological samples, labelled by radionuclide iodine 125, by carrying out the radioimmunological investigations, as well as, it is used for registration (recording) gamma-radiation with energy from 20 кeV to 1Mev in radioisotope diagnostics laboratories
Device can be delivered together with diagnostic preparations of State Enterprise "Radiopreparat" at INP AS RU.
|
The biological sample volume - |
no more than 2 ml |
| The activity determination range by iodine-125- | <from 17 to 1,7х105 Bк |
|
The non-stability of measurement within 24 work hour |
+- 3 % |
Institute of Nuclear Physics AS RU, Design Department with Experimental Pilot Plant
Phone: (998-71) 150-30-70, 289-34-41
Fax: (998-71) 150-30-70
e-mail: info@inp.uz